User Tools

Site Tools


ubitx:calibration

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
ubitx:calibration [2019/09/20 23:14]
f4ija
ubitx:calibration [2019/09/23 23:04] (current)
f4ija
Line 18: Line 18:
 (Please read the whole article of KD8CEC, it's well explained). (Please read the whole article of KD8CEC, it's well explained).
  
-So, I've tried this this a spreadsheet to make the calculations with the mean frequencies and you will find this in the [[https://​www.dropbox.com/​sh/​537byjdofw8a2mw/​AABylslZM-fazlWtRnez65kAa?​dl=0|DropBox folder of the whole project]] with the filename Master calibration.ods.+So, I've tried this this a spreadsheet to make the calculations with the mean frequencies and you will find this in the [[https://​www.dropbox.com/​sh/​537byjdofw8a2mw/​AABylslZM-fazlWtRnez65kAa?​dl=0|DropBox folder of the whole project]] with the filename ​**Master calibration.ods** in the **Tests** folder.
  
 It seems to work but the new calculated value is like a range which is getting narrower the more you test. It seems to work but the new calculated value is like a range which is getting narrower the more you test.
Line 29: Line 29:
  
 However, I think this method is quite simple and easy to measure by the community of WSPR spotters. Another useful thing with WSPR ! However, I think this method is quite simple and easy to measure by the community of WSPR spotters. Another useful thing with WSPR !
 +
 +==== Extra tests : electronics heat importance ====
 +After the conclusion of the calibration,​ I wanted to test if the heating of the electronics could have a noticable impact upon the deviation of the frequency.
 +
 +So, I've tested my Ubitx with a WSPR spotting just after a cold boot (after at least one day without turning it on) and after a while, at least 30 minutes.
 +
 +The results are in the Test folder, with the name **WSPR deviation heating up.ods.**
 +
 +After a cold start :
 +
 +{{ :​ubitx:​heatdeviation1.png |}}
 +
 +After at least 30 minutes, without changing everything else :
 +
 +{{ :​ubitx:​heatdeviation2.png |}}
 +
 +The result is much better !!
 +
 +Let's try after more than one hour :
 +
 +{{ :​ubitx:​heatdeviation3.png |}}
 +
 +OK, it's not better. Maybe there is not enough values to validate the results but it seems that there no improvements after 35 minutes.
 +
 +The point is that you need after all to wait before making some calibration to be sure to have right values and not fluctuing measures.
  
 ===== Calibrating the BFO ===== ===== Calibrating the BFO =====
  
  
ubitx/calibration.1569014064.txt.gz ยท Last modified: 2019/09/20 23:14 by f4ija